DC – PU/PIR insulation panel – Fire class EI 30

Application: Environments where high demands are placed on hygiene, including the food industry and the pharmaceutical industry, and where there is also a fire requirement of EI 30

Tried and tested: Over 45 years, the panel has been thoroughly tested in many different contexts and degrees of difficulty.

Assambly: Built-in locking system that ensures a tight vapor barrier, prevents water/dirt and bacteria in joints. Gives great disc effect in walls and ceilings which in turn minimizes costs for bearing steel.

Insulation: The PU/PIR foam insulates 60% better than mineral wool, does not absorb water.

Fire: Inquire about the many options.

Sustainability: Panels with PU/PIR foam could be reused even after many years as the insulation remains intact.

Gypsum boards on both sides
Panel thickness Weight kg/m2 U-value W/M2K
100 mm 30,3 0,28
125 mm 31,2 0,21
150 mm 32 0,17
175 mm 32,9 0,14
200 mm 33,8 0,12
225 mm 34,7 0,11
Production tolerances According to EN14509
Production measures Width: 1200 mm – Length: Up to 8800 mm
Fire approval EI30
Sound attenuation Contact DC-System for information
Tension table Contact DC-System or see it at www.dc-system.dk
Insulation PU/PIR foam between 2 pcs. embedded plasterboard
Surfaces 0.55 mm galvanized steel sheet, coated with 25 my polyester varnish – on both sides. This panel can, if desired,
supplied with other surface materials, e.g. 200 my plastisol, PVC Food Safe, stainless steel etc. The surfaces are hygienic and easy to clean.
Assembling The panels are supplied with tongue and groove joints and eccentric locks, which are embedded in the foam
Color The panel is delivered as standard grey/white RAL 9002. If other colors are desired – contact DC-System
Other things Need more information – contact DC-System. DC-System can, if desired, assist with measurement

DC's EI30 Insulation Panels: Optimal Fire Safety and Insulation for Demanding Indoor Environments

DC’s EI30 Insulation Panels: Optimal Fire Safety and Insulation for Demanding Indoor Environments
DC’s PU/PIR insulation panels with fire class EI 30 are specifically designed for interior use in buildings and are particularly suitable for areas with strict insulation and fire safety requirements. This includes cold storage and freezer rooms, the food industry, warehouses and stables, where both walls and ceilings require high insulation performance and surface protection.

The panel is equipped with a built-in vapour barrier and meets the requirements of fire class EI 30, ensuring optimal fire safety and resistance in the event of a fire. With its excellent insulation performance, it also helps maintain stable temperature conditions in cold and freezer rooms and other environments where temperature control is essential.

DC’s EI30 insulation panel can be used as a partition wall in fire compartment sections as it fulfils EI30 (BD30) requirements, making it ideal for dividing rooms into fire-resistant sections. The panel is particularly suitable for areas where extra protection against fire is needed and where there are special requirements for fire-retardant properties.

With DC’s PU/PIR insulation panels, you can be sure to fulfil both insulation and fire safety requirements in even the most demanding environments.

Read about one of our other panels

DC – PU/PIR insulation panel – floor with Masterboard
Application: Floors for freezer tunnels. Assambly: Built-in locking system that ensures a tight v...
DC – PU/PIR Hygienic insulation panel – Locking system
Application: Environments where there is a lot of cleaning and where there are generally high dem...
DC – Renovation panel
Application: Environments where high demands are placed on hygiene, including the food industry a...
DC – Fireproof Mineral wool panel – Roof
Application: All buildings where there are high fire requirements, but not freezer rooms. Assembl...