DC – Fireproof Mineral wool panel – Roof

Application: All buildings where there are high fire requirements, but not freezer rooms.

Assembly: The panel is assembled with an overlap on the upper steel plate and fixed with through sandwich screws.

Tried and tested: Over 15 years, the panel has been thoroughly tested in many different contexts and degrees of difficulty.

Fire: Inquire about the many options.

Panel type Core thickness U-value W/M2K U-value EN14509 Weight kg/m2 Fire resistance
DP-F 102 60 0,61 0,65 18,7 REI 30
DP-F 122 80 0,47 0,5 20,9 REI 90
DP-F 142 100 0,38 0,41 24,4 REI 120
DP-F 162 120 0,32 0,35 26,9 REI 120
DP-F 182 140 0,28 0,3 29,5 REI 120
DP-F 192 150 0,26 0,28 30,8 REI 120
DP-F 202 160 0,24 0,26 31,9 REI 120
DP-F 222 180 0,22 0,24 33,6 REI 120
DP-F 242 200 0,2 0,21 36,3 REI 120
Production tolerances According to EN 14509
Production measures Width: 1000 mm – Length: Max 15.6 m (extra long transport is required over 13.6 m length). ATTENTION! Be aware that deflections on long panels may occur under high loads
Fire approval According to EN 13501-1 Euroclass A2-s1, d0, non-flammable
Sound attenuation Approx. 32 dB (depending on frequency)
Tension table Contact DC-System or see it at www.dc-system.dk
Insulation Insulation core of mineral wool. Shear strength is achieved simultaneously with steel plate on the outside. Density, approx. 120 kg/m3, 14 kg/m3 on request. Capillary layer
Surfaces 0.6 mm galvanized steel sheet coated with 25 my polyester varnish – on both sides. ATTENTION! The safety film on the panel must be removed no later than 10 weeks after the production date
Assembling The panels are delivered with external overlap and internal tongue and groove assembly
Color The panel is supplied as standard with grey/white RAL 9002. If other colors are desired – contact DC-System
Other things Need more information – contact DC-System. DC-System can, if desired, be helpful with measurement

Reliable Fireproof Insulation with DC's Mineral Wool Panel

DC’s mineral wool panel provides a reliable solution with a focus on fire safety. Suitable for installation on various structures such as wood, steel and concrete, the panel ensures effective insulation without thermal bridges. The mineral wool on the edges of the panels is protected by plastic foil to prevent the absorption of building moisture.

Product specifications:
  • Material: Mineral wool
  • Installation: Quick and easy installation on various substructures
  • Protection: Plastic foil ensures against the absorption of building moisture
  • Suitable for: Industrial, agricultural and similar buildings with high fire safety requirements
Sustainability and Energy:

DC’s mineral wool panel not only contributes to fire safety, but also to sustainability and energy efficiency. By creating an effective thermal barrier, the panel helps reduce the need for heating and cooling, which in turn reduces energy consumption and CO2 emissions. This makes the panel an environmentally friendly choice that supports the creation of greener buildings and more sustainable communities.

Please note that the panel is not suitable for use in cold rooms.

Read about one of our other panels

DC – PU/PIR insulation panel – floor
Application: Floors for freezer tunnels. Assambly: Built-in locking system that ensures a tight v...
DC – Post Insulation panel – PU/PIR/mineral
Application: After insulation of existing homes, which must subsequently be finished with a plast...
DC – Mineral wool panel – Wall/Ceiling
Application: Office and industrial buildings where there are high fire requirements. Assembly: Th...
DC – PU/PIR insulation panel – Fire class EI 30